EN 5.998.4.0/07.24
2
TECHNICAL CHARACTERISTICS
1)
Operating pressure max. 350 bar
Flow rate max. 110 l/min
Internal leakage Leakage-free, max. 5 drops/min (0.25 cm³/min) at 350 bar
Pressure uid Hydraulic oil to DIN 51524 Part 1, 2 and 3
Ambient temperature range min. -20 °C up to max. +60 °C
Temperature range of pressurised uid NBR: min. -30 °C up to max. +100 °C
FKM: min. -20 °C up to max. +120 °C
Viscosity range min. 7.4 mm²/s up to max. 420 mm²/s
Filtration Permitted contamination level of operating uid as dened by ISO 4406
<210 bar Class 20/18/15 or cleaner
>210 bar Class 18/16/13 or cleaner
MTTF
D
150 – 1200 years, assessment according to DIN EN ISO 13849-1:2016, Table C.1,
Conrmation of ISO 13849-2:2013; Tables C.1 and C.2
Installation position user-denable
Materials Valve body: Steel
Spool: Steel, hardened and ground
Seals: NBR (standard)
FKM (optional)
Support rings: PTFE
Cavity FC12-2
Weight 0.36 kg
0.55 kg with coil
Electric system
Response time Energised: Approx. 30 ms Greatly increased reaction times possible for
other operating conditions.
De-energised: Approx. 70 ms
Type of voltage DC: DC solenoid
AC: AC with rectier integrated in the coil
Voltage tolerance ±15 % of nominal voltage
Nominal current at 20 °C 1.5 A at 12 V DC
0.8 A at 24 V DC
Duty cycle 100 % duty cycle (continuous operation)
up to max. 115 % of the nominal voltage at 60 °C ambient temperature
Coil design Coil ... 40-1836
1)
See “Conditions and Instructions for Valves” in brochure 53.000.