EN 5.998.4.0/07.24
1
PRODUCT ADVANTAGES
z Coil seals protect the solenoid system
z Wide variety of connectors available
z Excellent switching performance by high-performance HYDAC solenoid
z External surfaces with advanced corrosion protection thanks to ZnNi coating
(1,000 h salt spray test)
DESCRIPTION OF FUNCTION
When the solenoid coil is de-energised, the valve blocks ow in both directions. When
the solenoid coil is energised, there is free ow through the valve in both directions.
Notice:
Switching characteristics and response times are strongly dependent on the pressure
dierence and the ow rate during the switching process. This is especially the case for
valves with poppet seal.
FUNCTION
2/2 directional poppet valve
WS12W-01
Poppet type, pilot-operated, solenoid operated,
normally closed
Screw-in cartridge valve UNF – 350 bar
up to 110 l/min
up to 350 bar
2
1
1
2
EN 5.998.4.0/07.24
2
TECHNICAL CHARACTERISTICS
1)
Operating pressure max. 350 bar
Flow rate max. 110 l/min
Internal leakage Leakage-free, max. 5 drops/min (0.25 cm³/min) at 350 bar
Pressure uid Hydraulic oil to DIN 51524 Part 1, 2 and 3
Ambient temperature range min. -20 °C up to max. +60 °C
Temperature range of pressurised uid NBR: min. -30 °C up to max. +100 °C
FKM: min. -20 °C up to max. +120 °C
Viscosity range min. 7.4 mm²/s up to max. 420 mm²/s
Filtration Permitted contamination level of operating uid as dened by ISO 4406
<210 bar Class 20/18/15 or cleaner
>210 bar Class 18/16/13 or cleaner
MTTF
D
150 – 1200 years, assessment according to DIN EN ISO 13849-1:2016, Table C.1,
Conrmation of ISO 13849-2:2013; Tables C.1 and C.2
Installation position user-denable
Materials Valve body: Steel
Spool: Steel, hardened and ground
Seals: NBR (standard)
FKM (optional)
Support rings: PTFE
Cavity FC12-2
Weight 0.36 kg
0.55 kg with coil
Electric system
Response time Energised: Approx. 30 ms Greatly increased reaction times possible for
other operating conditions.
De-energised: Approx. 70 ms
Type of voltage DC: DC solenoid
AC: AC with rectier integrated in the coil
Voltage tolerance ±15 % of nominal voltage
Nominal current at 20 °C 1.5 A at 12 V DC
0.8 A at 24 V DC
Duty cycle 100 % duty cycle (continuous operation)
up to max. 115 % of the nominal voltage at 60 °C ambient temperature
Coil design Coil ... 40-1836
1)
See “Conditions and Instructions for Valves” in brochure 53.000.
EN 5.998.4.0/07.24
3
UNIT DIMENSIONS
2
1
76 max.
(2.99 max.)
Ø31.8
Ø1.25
62 max.
(2.44 max.)
40.3
(1.59)
13.1
(0.52)
2
(0.08)
45.9
(1.81)
* Tightening torque:
Steel housing (burst strength > 360 N/mm²): 119 Nm
Aluminium housing (burst strength > 330 N/mm²): 75 Nm
(With torque tool according to DIN EN ISO 6789, tool type II class A or B). Millimetre (Inch)
For more information, see “Operating conditions and instructions for valves” in brochure 53.000. Subject to technical modications.
Spanner width 32
Tightening torque*
23.8
(0.94)
Tightening torque* 4 Nm
After loosening the mounting
nut, the coil can be rotated
through 360° and removed.
Ø22.23
Ø0.88
1 1/16-2 UN-2A
76.5
(3.01)
65
(2.56)
50.8 (2) thick
2
1
6.5
(0.26)
26.6
(1.05)
76.5
(36.01)
57.2
(2.25)
8.6
(0.34)
75 max.
(2.95 max.)
61 max.
(2.40 max.)
Ø36.3
(Ø1.43)
To actuate the valve manually, remove
protective cap and turn the rotary knob
anticlockwise.
EN 5.998.4.0/07.24
4
MODEL CODE
WS12W – 01M – C – N – 24 DG
Designation
2/2 directional poppet valve, UNF
Version
01 = standard
01M = with manual override
Type of connection
C = Screw-in cartridge valve
Seal material
N = NBR (standard)
V = FKM (optional)
Nominal voltage for actuating solenoid
DC voltage:
12 = 12 V DC
24 = 24 V DC
AC voltage (rectier integrated into coil):
115 = 115 V AC
230 =230 V AC
Coil design (type 40-1836) Number of pins Connection Protection class
DC:
DG = design A acc. to DIN EN 175301-803 3-pole radial IP65
DK = KOSTAL plug connector M27x1 2-pole radial IP65/IP67
DL = two ying leads 0.75 mm² x 457 mm (18'') 2-pole radial IP65/IP67
DN = DEUTSCH plug connector DT04-2P 2-pole axial IP67/IP69
DO = M12 plug connector 4-pole radial IP65
DT = AMP Junior Timer 2-pole radial IP65/IP67
DU = AMP Junior Timer 2-pole axial IP65/IP67
AC:
AG = design A acc. to DIN EN 175301-803 3-pole radial IP65
Further versions on request.
CAVITY
FC12-2
*
Permitted boring zone (for block design) Millimetre
**
Sharp edges should be avoided by using a radius of 0.1 mm to 0.2 mm Subject to technical modications
Rz 10
Rz 6.3
Ra 6.3
38
1
±0.2
60° **
22.225
+0.05
[
21.23±1]
36.52
±0.2
47.5
±0.5
49.5
±0.5
21.6
±1
1 1/16-12 UN-2B
16.8 min.*
34.3 max.*
Max. Nominal-
Ø:
46.7
X
Rz1 10
Rz 6.3
Rz 6.3
VE
0.05
A B
0.05
A B
PD
0.02
B
A
R0.2
±0.2
R0.15
±0.05
45°
3.5
±0.2
30°
±1°
29.25
±0.05
X 4 : 1
Rz2 6.3
0.1
ACS
B
0.05
A B
ACS
1
2
Ø
6
Ø
21
Fitting Depth
(Included angle)
VE = Visual Examination
EX.:
EN 5.998.4.0/07.24
5
SAMPLE CHARACTERISTICS
Δp/Q - characteristics measured at ν = 33 mm
2
/s, T
Oil
= 46 °C
MATERIAL OVERVIEW
Standard models
Designation Part no.
WS12W-01-C-N-12DG 4802490
WS12W-01-C-N-24DG 4802491
WS12W-01M-C-N-12DG 4802492
WS12W-01M-C-N-24DG 4802493
Further versions on request.
Spare parts, seal kits
Designation Material Code Part no.
FC12-2 seal kit NBR FS UNF 12/S2/N 3651537
FC12-2 seal kit FKM FS UNF 12/S2/N 3651539
Housing
Designation Material Code Pressure max. Connections Weight Part no.
Inline connection housing Aluminium, anodised FH122-AB6 210 bar G3/4" 0.47 kg 3053843
Inline connection housing Steel, zinc-plated FH122-SB6 350 bar G3/4" 0.16 kg 3053782
Cavity tools
Designation Part no.
Countersink 176951
Reamer 176952
NOTE
The information in this brochure relates to the operating conditions and elds of application
described. For applications and operating conditions not described, please contact the
relevant technical departments.
Subject to technical modications.
Documents are only valid if they have been obtained via the website and are up-to-date.
HYDAC FLUIDTECHNIK GMBH
Justus-von-Liebig-Str.
66280 Sulzbach/Saar
Germany
Phone: +49 6897 509-01
Email: valves@hydac.com
Internet: www.hydac.com
1 → 2, 100% I
max
2 → 1, 100% I
max
200
175
150
125
100
75
50
25
40
Pressure drop Δp
Flow rate Q
0
2
4
6
8
10
12
10 20 30 50 60
70 80
90
100 110
0 10 15
20 25
[bar][psi]
[l/min]
[gpm]
0
14
0
5